Products
-
-
-
-
Contact Us
Fully compatible with 15kW-100kW | Integrated Photovoltaic + Energy Storage + Diesel
Consult Solution → Learn More →
Fully compatible with 150kW-500kW | Integrated Photovoltaic + Energy Storage + Diesel
Consult Solution → Learn More →Specifications and Parameters
Numerical Reference for Diesel Generator Sets | Diesel Saver Fuel-Saving System | ||||||||||
Generator set | Diesel generator (kW) | Runtime | Voltage level | Frequency | Photovoltaic storage system model | Rated power | EPS peak power (10S) | Off-grid nominal output current | Photovoltaic power generation output (kWh/day) | Save diesel fuel (L/month) | Land area of the solar-plus-storage system (m²) |
Small unit | 15 | 6 | 380V/400V | 50Hz/60Hz | Diesel Saver 15kW/6H | 20kW | 35kW | 29A | 84 | 757 | 120 |
| 12 | Diesel Saver 15 kW/12 h | 30kW | 39.3kW | 43.5A | 199 | 1793 | 280 | |||
| 24 | Diesel Saver 15 kW/24 h | 60kW | 78.6kW | 87A | 354 | 3188 | 500 | |||
30 | 6 | Diesel Saver 30 kW/6 H | 30kW | 39.3kW | 43.5A | 177 | 1594 | 250 | |||
| 12 | Diesel Saver 30 kW/12 H | 60kW | 78.6kW | 43.5A | 354 | 3188 | 500 | |||
| 24 | Diesel Saver 30 kW/24 h | 90kW | 117.9kW | 130.5A | 638 | 5739 | 900 | |||
50 | 6 | Diesel Saver 50 kW/6 H | 60kW | 78.6kW | 87A | 354 | 3188 | 500 | |||
| 12 | Diesel Saver 50 kW/12 h | 120kW | 157.2kW | 174A | 567 | 5101 | 800 | |||
| 24 | Diesel Saver 50 kW/24 h | 180kW | 196.5kW | 217.5A | 1196 | 10760 | 1700 | |||
100 | 6 | Diesel Saver 100 kW/6 h | 120kW | 157.2kW | 174A | 567 | 5101 | 800 | |||
| 12 | Diesel Saver 100 kW/12 H | 180kW | 235.8kW | 261A | 1196 | 10760 | 1700 | |||
| 24 | Diesel Saver 100 kW/24 H | 300kW | 393kW | 435A | 2258 | 20325 | 3100 | |||
Large unit |
150 | 6 |
380V/400V |
50Hz/60Hz | Diesel Saver 250kW/6H | 250kW | 350kW | 379.8A | 677 | 6097 | 1000 |
12 | Diesel Saver 375 kW/12H | 375kW | 525kW | 569.7A | 1355 | 12195 | 1900 | ||||
24 | Diesel Saver 500 kW/24 H | 500kW | 700kW | 759.6A | 2710 | 24389 | 3700 | ||||
200 | 6 | Diesel Saver 250 kW/6H | 250kW | 350kW | 379.8A | 917 | 8249 | 1300 | |||
12 | Diesel Saver 500 kW/12 H | 500kW | 700kW | 759.6A | 1833 | 16499 | 2500 | ||||
24 | Diesel Saver 750 kW/24 H | 750kW | 1050kW | 1139.4A | 3587 | 32280 | 4900 | ||||
250 | 6 | Diesel Saver 375 kW/6H | 375kW | 525kW | 569.7A | 1076 | 9664 | 1500 | |||
12 | Diesel Saver 500 kW/12 H | 500kW | 700kW | 569.7A | 2232 | 20085 | 3100 | ||||
24 | Diesel Saver 875 kW/24 H | 875kW | 1225kW | 1329.3A | 4463 | 40171 | 6100 | ||||
300 | 6 | Diesel Saver 375 kW/6H | 375kW | 525kW | 569.7A | 1315 | 11836 | 1800 | |||
12 | Diesel Saver 750 kW/12H | 750kW | 1225kW | 1139.4A | 2630 | 23672 | 3600 | ||||
24 | Diesel Saver 1000 kW/24 H | 1000kW | 1400kW | 1519.2A | 5101 | 45910 | 7000 | ||||
350 | 6 | Diesel Saver 500kW/6H | 500kW | 700kW | 759.6A | 1594 | 14347 | 2200 | |||
12 | Diesel Saver 750 kW/12H | 750kW | 1050kW | 1139.4A | 3180 | 27976 | 4300 | ||||
24 | Diesel Saver 1250 kW/24H | 1250kW | 1750kW | 1899A | 5978 | 53800 | 8100 | ||||
400 | 6 | Diesel Saver 500 kW/6H | 500kW | 700kW | 759.6A | 1753 | 15781 | 2400 | |||
12 | Diesel Saver 750 kW/12H | 750kW | 1050kW | 1139.4A | 3587 | 32280 | 4900 | ||||
24 | Diesel Saver 1250 kW/24H | 1250kW | 1750kW | 1899A | 6775 | 60974 | 10000 | ||||
450 | 6 | Diesel Saver 500 kW/6H | 500kW | 700kW | 759.6A | 1913 | 17216 | 2600 | |||
12 | Diesel Saver 750 kW/12H | 750kW | 1050kW | 1139.4A | 3826 | 34432 | 5200 | ||||
24 | Diesel Saver 1250 kW/24H | 1250kW | 1750kW | 1899A | 7572 | 68147 | 10500 | ||||
500 | 6 | Diesel Saver 625 kW/6H | 625kW | 875kW | 949.5A | 2192 | 19727 | 3000 | |||
12 | Diesel Saver 750 kW/12H | 750kW | 1050kW | 1139.4A | 4304 | 38736 | 5900 | ||||
24 | Diesel Saver 1250 kW/24H | 1250kW | 1750kW | 1899A | 8413 | 75719 | 12000 |
Note: Based on a diesel price of USD 1.5 per liter, the payback period for the solar–storage system is approximately two years.
Integrated Photovoltaic–Battery–Diesel Microgrid System
Schematic Diagram of a Small-Scale Unit System (15 kW–100 kW)
System Schematic Diagram for 150 kW–500 kW Large-Scale Units
Five Major Advantages
Ultimate fuel efficiency
Intelligent matching for each model of diesel generator reduces diesel consumption by 80%–90%.
Monthly savings of 700–75,000 L
Standardized compatibility and rapid deployment—no device modification required; plug in and use.
Intelligent Priority Power Supply
Intelligent interlocking: diesel generator first, followed by photovoltaic, then batteries, and finally diesel; unattended operation.
Lithium iron phosphate battery cell, 8,000 cycles
Cycle ≈ 10-year lifespan, all fields
Smart Surveillance System
Suitable for multiple scenarios
Off-grid / Grid-connected / Construction site / Mine /
Base station/Campsite/Island/Commercial/
Industry/Agriculture
Success Stories
Consulting Solutions
Whether you have project‑related inquiries, require customized solutions, or would like to learn more about our products, our expert team is here to assist you at any time.
Global Headquarters
China · Baoding
Address: No. 88, Hengyuan West Road, National High-tech Zone, Baoding, China
Phone:+86 0312 7510213(Domestic Business)
Phone:+86 0312 7510212(International Business)
Email:sales@ycsolar.com